1.饲料驱动系统
The feed drive system is divided into DC feed drive and AC feed drive. The failures can be roughly divided into three categories. One is to display alarm information on CRT by using the diagnostic program of software; Second, the hardware on the speed control unit (LED indication, fuse fusing, etc.) is used to display the alarm; Third, there is no fault with any alarm indication.
2. Software alarm form
通过系统的饲料驱动器的监控和报警,在CRT上显示这种警报。第一种情况是伺服馈送系统的错误警报;大多数这些警报是由速度控制的故障引起的,或者与NC的位置控制或伺服信号有关的部分失败;第二种情况是由相关检测元件(速度测量电机,旋转变压器或脉冲编码器)引起的故障;第三种情况是关于过热的警报,例如伺服单元,变压器和电机。
3.硬件报警表
包括报警指示灯和熔断器熔断器速度控制单元,各种开关的跳闸(用于保护)等。报警指示器的含义随着速度控制单元的设计而变化。通常,有以下情况:
① high voltage alarm. The reason for this kind of alarm is generally that the input AC power supply voltage exceeds 10% of the rated value or the insulation capacity of the motor decreases. A megger can be used to measure the insulation capacity of the motor.
②高电流报警。这种警报主要是由于速度控制单元上的电源驱动元件晶闸管模块或晶体管模块的损坏。在电源故障的情况下,使用万用表来测量模块的集电极和发射器之间的电阻。如果它小于10Ω,则表示模块已损坏。
③低压报警。
④过载警报。这种警报的原因是机械负荷是异常的,或者速度控制单元上的电动机电流的上限设置得太低,并且有许多机械负载,由于长期的服务时间,这严重佩戴设备器材。可以更改电流的设置值。
⑤速度反馈报警。这种警报主要由伺服电机的速度或位置反馈线差或连接器接触不良引起的。它也可能是NC中反馈信号处理模块的问题。
⑥保险丝燃烧或断路器跳闸。这种警报有很多原因,必须根据具体情况确定。如果在更换保险丝后仍发生警报,则必须找到融合的原因。
⑦保护切换动作。如果这种警报是一个明显的保护开关动作,原因也很简单。重复操作以避免它,例如旅行开关。如果变压器过热并且空气开关跳闸,则有必要找出原因。有些是由设定值问题引起的,并且有些是通过在处理过程中过热引起的。
⑧ Failure without alarm display. Such failures include machine tool vibration, machine tool out of control, excessive machine tool noise, etc. in case of such situations, comprehensive consideration shall be made and judgment shall be made according to the actual situation.